-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Eight detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
Key Features:; Up to 8 repeaters per CFP master Includes its own Mains power supply that requires its own standby battery supply Provides the user with access to all AL1 and AL2 functions Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM Attractive flush or surface mountable plastic lid and enclosure - no bezel required
-
Third-party certified to EN54-3 (Sounders) and EN54-17 (Isolators) by Intertek (pending) Impressive 90dB(A) sound output @ 1m Onboard short-circuit loop isolator 5mA alarm current @24V DC (sounder on max) Attractively finished in red polycarbonate Group addressing facility allows multiple devices to be operated simultaneously 7 selectable volume levels and up to 15 selectable tone pairs Attractive compact design - just 102mm diameter, 63mm deep Includes an integrated sounder to base locking mechanism IP21C rated Low current consumption means multiple devices can be connected to the loop DIP switch addressed Simple ‘click and twist’ design and easy-fit base ensures rapid installation time Also available in a white plastic housing (order code BF450A/CX/SW)
-
-
Key Features:; Third-party certified to EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'W-3-3.1' light distribution when wall mounted (min. 0.4 lux over a 2.4 x 3.5m cuboid area). Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. IP21C rated.
-
Key Features:; Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area). Supplied with a BF431QCP quick connect plate and detector spur wires. Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. IP21C rated.
-